info@wsngn.com
logologo
Water Conditoners and Water Treatment
  • en 
    • Function
      • Purpose and use
      • Principle of operation
      • Features
      • Сomparison to others
      • FAQ
    • Catalog
      • Industrial water conditioners
      • Water conditioners (flocculation)
      • Model selection
      • Location
      • Installation
    • Testimonials
      • Heat-exchangers
      • Industrial boilers
      • Pipes descaling
      • Reagents
      • Swimming pools
    • Articles
      • Water treatment
      • Energy saving
      • Limescale protection
      • Water filtration
      • Corrosion protection
    • Contacts
    HomeWS-168F
    ferrite water conditioner WS168

    WS-168F

    Non-chemical ferrite water conditioner (electronic decalcificator, electronic water softener), model WS-168F with enhanced flocculation and anti-bacteria effect.

    The action of the water conditioner is aimed to reduce of operating costs, to ensure industrial safety and prevent accidents due to bio-fouling, bacteria growing inside the pipes, descaling (decalcification). Water conditioner improves the efficiency of water filtration, reduces the consumption of chemicals for the water treatment, inhibits limescale formation during operation in chillers, condensers, cooling towers, heat-exchangers, inhibits internal corrosion.

    WS-168F water conditioner can be used as a part of the water treatment system for the swimming pools, water parks, fish pools. The device can be used for comprehensive protection of bio-fouling, lime-scale, internal corrosion of chillers, condensers, heat-exchangers, cooling towers, water lines.

    Category: Water conditioners (flocculation) Tag: pipe d.6″ (150 mm)
    • Description
    • Additional Information

    Product Description

    Model for mounting on pipes with outside diameter up to 6.6” (168mm, DN150). Can be installed on smaller diameter pipe.

    Ferrite type water conditioner. The device transfer electromagnetic field energy into the water with a ring magnetic core assembled from ferrite plates over the pipe.

    Power – AC 110-220V. Power consumption – 8 watts.

    The device comprises the main unit, power supply, ferrite plates, plastic bolts and nuts for ferrite plates mounting and clamps for fixing device on the pipe.

    The water conditioner is mounted over the pipe, without cutting.

     

    Location:

    To improve the efficiency of filtration water conditioner should be located on the pipe between the pump and sand filter, closely to the pump. The distance (along the pipe) from the device to the filter should not be less than 5 meters. Pipe shape is not important. Possible to install water conditioner before the pump.

    For the protection from bio-fouling and lime-scale for chillers, heat-exchangers, cooling systems, locate the water conditioner on a pipe with the cool water, between the circulating pump and chiller, approximately in the middle of the pipe. Pipe length should be at least 2 meters. Pipe shape is not important. Recommend to install a second water conditioner on the pipe with warm water, between chiller and cooling tower to enhance the effect, particularly for bacteria and bio-fouling control

    Please contact authorized distributor about location details.

     

    Water Engineering water conditioners with flocculating effect:

    — cause water coagulation (consolidation) of colloidal and suspended particles in the water;
    — prevent line-scale formation on the internal surfaces of piping and various equipment;
    — inhibit internal corrosion due to passivation effect and due to inhibit of microbial corrosion;
    — inhibit the grow of some types of bacteria.
     
    The result of the combined action is:
    — increasing the efficiency of filtration;
    — reducing of maintenance costs;
    — reducing the consumption of water for back-wash of the filters;
    — reducing reagent consumption (directly and the consumption of chemicals for cleaning surfaces during maintenance as well).
     

    Applications:

    1. For open cooling systems – prevent bio-fouling (bacteria, microscopic algae, fungus) on the internal surfaces of piping and equipment; for fresh water and for sea water applications.
    2. For closed cooling systems like central air-conditioning at office buildings, shopping centers, etc., to prevent bio-fouling and microbiological corrosion.
    3. For process water at the factories – inhibition of internal corrosion, lime-scale; improving of the efficiency of equipment operation; increasing the interval between shutdowns for cleaning; reducing the consumption of chemicals.
    4. For drinking water systems water treatment systems – reducing consumption of the flocculant, coagulant, improving the quality of the water;
    5. For swimming pools and water parks – reducing consumption of the flocculant, coagulant, improving the quality of the water, reducing consumption of sodium hypochlorite.

    Additional Information

    Weight 14.3 lbs
    Dimensions 22.5 x 15 x 4.7 in

    Related Products

    • ferrite water conditioner WS132

      WS-132F

      Category: Water conditioners (flocculation) Tag: pipe d.5″ (125 mm)
    • ferrite water conditioner WS115

      WS-115F

      Category: Water conditioners (flocculation) Tag: pipe d.4″ (100 mm)
    • ferrite water conditioner WS62

      WS-62F

      Category: Water conditioners (flocculation) Tag: pipe d.2" (50 mm)

    Search

    Product Categories

    • Industrial water conditioners
    • Water conditioners (flocculation)

    Product Tags

    pipe d.1.6" (40 mm) pipe d.2" (50 mm) pipe d.4″ (100 mm) pipe d.5″ (125 mm) pipe d.6″ (150 mm)

    Model selection

    Home

    • Principle of operation
    • Features
    • Comparison with others

    Models

    • Model selection
    • Location of the unit
    • Installation

    Service and operation

    • Checking
    • FAQ
    • Contacts

     

    e-mail: info@wsngn.com

    Copyright 2016-2018. All Rights Reserved by Water Systems Engineering LLC. | Sitemap